Modbus Slave Serial
Modbus TCP
The following settings are special to Modbus TCP
mode of the serial port.
Setting | Description | Default |
---|---|---|
Enable | Enable Modbus TCP | disable |
Port | Listen Port, range 1-65535 | 502 |
DI Address | DI Address, range 0-255 | 0 |
DO Address | DO Address, range 0, 2-255 | 0 |
Modbus RTU
The following settings are special to Modbus RTU
mode of the serial port.
Setting | Description | Default |
---|---|---|
Enable | Enable Modbus RTU | disable |
Serial Port | Serial port, range 1-65535 | |
Slave ID | Slave ID on the link | 1 |
DI Address | DI Address, range 0-255 | 0 |
DO Address | DO Address, range 0, 2-255 | 0 |
Modbus RTU Over TCP
The following settings are special to Modbus RTU Over TCP
mode of the serial port.
Setting | Description | Default |
---|---|---|
Enable | Enable Modbus RTU Over TCP | disable |
Slave ID | Slave ID on the link | 1 |
Device ID | Device ID on the link | 1 |
Reconnect Interval | Client reconnect when lost connection, in seconds | 1 |
DI Address | DI Address, range 0-255 | 0 |
DO Address | DO Address, range 0, 2-255 | 0 |
Server List | List of Modbus server address and port |