Modbus Master Serial
Configure as modbus master and poll modbus slave device, redirect packet to predefined server.
TCP Forwarding
| Setting | Description | Default |
|---|---|---|
| Name | Unique identity of channel | |
| IP Address | IP address of redirect server | |
| Port | Port of redirect server |
Channel
| Setting | Description | Default |
|---|---|---|
| Name | Unique identity for channel | |
| Slave ID | Modbus Slave ID | |
| Address | Read start address | |
| Number | Number need to read | |
| Type | Modbus read type | |
| Link | Transportation protocol | tcp |
| IP Address | IP address of modbus slave | |
| Port | Port of modbus slave | |
| Sign | Channel is signed or unsigned | unsigned |
| Decimal Place | Indicate the dot place of channel |
Modbus Master
The following settings are special to Modbus Master mode of the serial port.
It should configure channel before configuring master.
| Setting | Description | Default |
|---|---|---|
| Enable | Enable Modbus Master | disable |
| Reading interval | Device DTU read cycle interval, in seconds | 0 |
| Maximun Retries | Maximun retries when reading data fail | 3 |
| Response Timeout | Device response timeout interval, in seconds | |
| Excution Interval | Execution interval between command, in milliseconds | 1 |
| Channel Name | Previous configured channel name |